Teknoizosıva Thermal Insulation Board Plaster

Teknoizosıva Thermal Insulation Board Plaster
Thermal Insulation Board Plaster
  TDS Technical Document Sheet   

  TSE Document   

Product Description
Cement based polymer modified, fiber reinforced special plaster which is used for plastering boards (EPS, Mineral Wool, XPS and ete) in external and interior applications.

Areas of Usage
• For plastering the heat insulation board stop in outer wall heat insulation system,
• For plastering on concrete, gas concrete, hollow foam at inner and outer spaces,
• At residences, shopping centers and hospitals,
• For horizontal , vertical and overhead applications.
• For all kinds of reinforced concrete civil engineering constructions.

Features and Benefits
• it is easy to apply and to give shape.
• it is a long lasting product in various weather conditions.
• it has high impact resistance thanks to polymer powders in its formulation
• it has vapor permeability.
• it is not flammable.
• Paint can be applied directly on it.
• it tolerates the shrinkage and expansion caused by temperature differences and minimizes the risk of cracking thanks to fibers in its structure.

Application lnstructions
Surface Ouality: The surfaces must be clean, smooth, solid and free of substances and residuals preventing adhesion such as all kinds of dust, grease, rust, molding oil, and detergents, ete. The surfaces must be smooth, the weak parts must be removed. lf there are cracks, pits on the surfaces or walls which the applications shall be made, they must be repaired with appropriate TEKNOREP repairing mortars.

Surface Preparation: The gaps remaining between the heat insulation boards should be filled by small pieces which shall be cut again from these boards. Before plastering application, the places which wall plugs shall be placed are opened on the board viaa punch attached to the drill bit. The wall plugs are driven. Plug choice must be made depending on the thickness of the concrete, brick, gas concrete, and heat insulation board. At least 6 plugs must be driven for 1 m2 area. As the story height increases, the number of plugs must also be increased. Opening the plugs properly, increases the quality ofthe application.

lf the wide round end (head) remains excessively outside or excessively inside of the board plain, a bad appearance results after the rain or with the sunlight. The locations of the plugs become clear.

After the plugging process finishes, TEKNOIZOSIVA application can be started. 6 - 7 liters of clean and clear water at normal ambient temperature is added into a clean pot purged from all materials that could prevent adhesion. TEKNOIZOFIX in the 25 kg bag in powder form, is emptied in the pot filled with water. it is stirred with a low-speed mixer until a smooth and homogeneous appearance is obtained. Mixture period must be minimum 5 minutes. The mortar obtained at the end of the process should be rested for 3 m., and stirred again for 2 m. until it becomes homogenous TEKNOIZOSIVA is applied on heat insulation boards after plugging process finishes, and on heat insulation boards having a thickness of 4 mm via 1O x1O notched steel trowel.

Application Notes / Restrictions
The alkali resistant glass fiber mesh (160 gr/m 2) is overlapped 1O cm, pressed 1-1 ,5 cm as to be near to the external wall by trowel before the plaster dries, and plaster surface is leveled out. An additional plaster mesh reinforce and TEKNOIZOSIVA application must be done on locations where sudden cross-sectional changes exist such as doors and windows. it is recommended to prefer meshed corner profile for the profile applications made to ensure the structure edges to be smooth. Ambient temperature and surface temperature should be between minimum +5°C and max +30°C during application or drying.

• For Mineral wool applications TEKNOIZOSIVA Thermal lnsulation Board Plasterfirstly should be applied as primer to the surface.
• TEKNOIZOSIVA should not be applied on places having direct sunlight, in rain and strong wind.
• The product should be protected against frost until it is set. The application should be protected against wetting due to rain orvarious reasons until its drying period completed.
• in case the ambient and surface temperature exceeds +25°C, the surface should be wetted by spraying method (with non-pressurized water) at certain intervals in order to prevent sudden dehydration and ensure the plaster sets in a good manner.
• The surface should be covered without being exposed to excessive dew, humidity and rain after Plaster Mortar application.
• Decorative plaster application can be made 1 day after the application for summer season and 2 days after the application for winter season.
• Product may irritate the skin in case of contact. Work clothes, protective gloves, mask and goggles should be used. Before starting to work, protective cream may be put on hands. in case the mortar contacts with eyes, eyes should be washed immediately with warm water, and medical advice should be get.
• Do not add foreign substances.
• Ensure that the rock wool plate is dry and have sufficient resistances for the applications to be made on rock wool plates.

    Have questions? Do you needed more information about