Tekno Yapi Kimyasallari
TR FR NL

Waterproofing Products

Acrylic, polyurethane and bitumen based waterproofing products.

CATEGORIES TECHNICAL PRODUCT
SHEETS CAN DOWNLOAD HERE
TSE DOCUMENT
DID YOU SEE?
CE DOCUMENT
DID YOU SEE?
OUR CATALOG YOU CAN
DOWNLOAD AS PDF

Teknomer 200 Ex W Flexible Waterproofing

Teknomer 200 Ex W Flexible Waterproofing
Flexible Waterproofing
  TDS Technical Document Sheet   

  CE Document   

  TSE Document   

Product Description
UV resistant, two component, white colored, cement and acrylic based , polymer reinforced, with special additives, fully elastic, waterproofing material. it is applied internally or externally on concrete, curtain and cement based plots against leakage and surface waters.

Areas of Usage
• Houses, shopping centers, hospitals,
• in vertical and horizontal applications, both indoors and outdoors,
• in its basic insulation and retaining walls,
• in facilities such as hot springs and baths,
• Water storage, swimming and ornamental pools,
• Terraces, balconies and fences without the need to cover it,
• it is used in wet spaces such as bathroom, wc, balcony.

Features and Benefits
• No need for water,
• Can be applied manually or by spraying,
• Theworking period is long,
• it has UV resistance,
• it does not shrink or crack,
• it can be applied to fresh screed and concrete surfaces thanks to crack bridging feature,
• it prevents carbonation in concrete,
• it does not contain corrosive and toxic substances and can be used in drinking water tanks.
• Protect concrete against sea water and carbon dioxide gas to ice-melting salts such as calcium and sodium chloride.
• it has high resistance to chlorine ions.

Application lnstructions
Surface Quality: The surfaces must be clean, smooth, solid, free from any antiadhesive substance such as dust, oil, dirt, rust, mold oil, detergent and waste. lf there is segregation in concrete, it should be discarded and loose parts should be removed, weak parts should be removed. lf there is crack, hollow on the floor or wall to be applied, it should be repaired with appropriate TEKNOREP repair mortars. Make sure that the slab or concrete is thrown in the direction of the water stream. The correct control of the curve is made in the following way. Beginning from the beginning to the gauge, put a scale on it. lf it is determined that there is no inclination or reverse slope in the control result, the application should not be started and the direction of the water flow should be adjusted by performing concrete and slab treatment. lf necessary, additional screed or concrete must be poured. Surface Preparation: lf the surface to be insulated is dry, it should be wetted and ready to be applied to the water. Tapered corners and edges should be chamfered with TEKNOREP 300 thick repair mortar. TEKNOMER Champer Tapes should be applied to all the corners beforehand on ceramic floors and wet rooms and balconies.

20 kg of powdered mortar should be mixed thoroughly so that no lumps are left by pouring slowly onto ı O I of liquid component. it is recommended that the mix be made with a low speed mixer less than 500 rpm. For the mortar to mature, it should be rest for 3 minutes and it should be mixed again for  2 minutes before application. The prepared mortar should be applied as 2 coats with roller or brush. Wait 5-6 hours depending on the temperature between coats. The coats should be applied perpendicular to each other. A total application thickness of 2-3 mm will suffice.

After TEKNOMER 200 EX W is thoroughly mixed and rested for 3-5 minutes, the water is applied to the saturated surface with the aid of brush and / or trowel without losing its moisture. After receiving the first set of material, 2. layer application is done in the perpendicular direction of the first layer application. lf desired, it can be used as carrier glass fiber reinforcement throughout the floors. Waiting time between floors; After the application of the first coat, when there is no mark on the fingers in the manual control, it can be passed to the other floors. 

Application Notes / Restrictions 
• Care should be taken not to damage the insulation material mechanically during the coating process.
• Since it's cement based, do not breathe it dust, prevent contact it with skin and hands.
• Do not apply to wood, chipboard, mdf, plywood, PVC and metal surfaces.
• Only the liquid should be used in the mixture. Absolutely no water should be added.
• Foreign materials should not be added.
• Protection is required to achieve long-term performance expected from the product. Tiles, ceramics, plaster and screed should be applied after 3 days in order to protect against punctures, scratches and crushes which may occur after application.
• it must be protected after application against adverse weather conditions such as direct sunlight, high air temperature (above +35°C), rain and frost. The product should be cleaned thoroughly with water and detergent before it is fully cured and hardened.
• lmmediately after application, before hardened, the equipment should be cleaned with water.
• After the product is hardened, it should be cleaned by mechanical methods



    Have questions? Do you needed more information about
    an product or you need a solution? Contact Us Now